Trace moisture analyzer
Classification:
Keyword:
- Performance Specification Table
- Technical parameter table
-
- Commodity name: Trace moisture analyzer
- Commodity ID: Puren-B H2O
- 副标: Pure<sup>n</sup>-B H<sub>2</sub>O
- Minor component: H2O
- Industry use: Special gas industry,Air separation field,Hydrogen energy,Semiconductor Manufacturing
- Product model: Puren系列
• PPB level measurement accuracy • Absolute measurement (no calibration required) • Real time online measurement • Low cost, maintenance free (no need for regular replacement/maintenance of sensors) • Fast response time • Minimal touch control, data transmission
Performance
-
Applicable gases: Most toxic and inactive gases
-
Detection range: see the technical parameter table for details
-
Lower limit of measurement: see technical parameter table for details
-
Sensitivity: ± 0.75% or 1/3LDL
-
Accuracy: ± 3% or LDL
-
Response speed:<1minute to 90%
Electronic parameters
-
Alarm indication: system alarm
-
Power supply requirements: 100-240VAC, 50/60Hz
-
Power: 40W (MAX)
-
User interface: 7-inch LCD display screen
-
Signal output: 4-20mA output, RS485 output,
adaptive network, RS-232 serial communication
Air system and conditions
-
Working environment temperature: 10 ℃~40 ℃
-
Working environment relative humidity: 30% to 80% (without condensate)
-
Storage temperature: -10 ℃ -40 ℃
-
Pipeline material: 316L stainless steel, Ra<0.25 μ M
-
Leak detection test:<1 × 10-9mbar l/sec
-
Inlet pressure: 0.05-0.8MPa
-
Maximum flow rate: approximately 1.5slm
-
Inlet gas temperature: up to 60 ℃
-
Inlet and outlet gas circuit: 1/4VCR male
Other
-
Size: 630mm × 210mm × 220mm
-
Weight: 10Kg
-
Appearance: inclined or vertical panel
-
Tested gas and background gas
H2O in N2
H2O in H2
H2O in He
H2O in Ar
H2O in O2
H2O in CO
H2O in CO2
H2O in COS
H2O in Ne
H2O in Kr
H2O in Xe
Measuring range
0-20ppm
0-16ppm
0-4ppm
0-9ppm
0-12ppm
0-24ppm
0-25ppm
0-23ppm
0-5ppm
0-11ppm
0-13ppm
Lower limit of measurement
1.0ppb
1.0ppb
0.25ppb
0.6ppb
0.7ppb
1.5ppb
2.0ppb
12.0ppb
0.3ppb
0.6ppb
0.8ppb
Sensitivity
0.4ppb
0.4ppb
0.1ppb
0.2ppb
0.25ppb
0.5ppb
0.7ppb
4.0ppb
0.1ppb
0.2ppb
0.3ppb
Tested gas and background gas
H2O in SF6
H2O in NF3
H2O in CF4
H2O in C2F6
H2O in C3F8
H2O in C4F6
H2O in C4F8
H2O in CDA
H2O in Cl2
H2O in HCl
H2O in HBr
Measuring range
0-15ppm
0-20ppm
0-15ppm
0-15ppm
0-20ppm
0-25ppm
0-20ppm
0-18ppm
0-25ppm
0-50ppm
0-100ppm
Lower limit of measurement
1.0ppb
2.5ppb
4.0ppb
3.0ppb
3.0ppb
200ppb
3.0ppb
1.0ppb
1.5ppb
3.0ppb
12.0ppb
Sensitivity
0.4ppb
0.9ppb
1.2ppb
1.0ppb
1.0ppb
100ppb
1.0ppb
0.4ppb
0.5ppb
1.0ppb
4.0ppb
* Note: If Cl2, HCl, and HBr need to be measured, Hastelloy alloy should be used as the gas path material
Intent Message
* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.
Related Products