Trace hydrogen chloride analyzer
Puren-B HCl

Trace hydrogen chloride analyzer


Keyword:


• PPB level measurement accuracy • Absolute measurement (no calibration required) • Low cost, maintenance free (no need for regular replacement/maintenance of sensors) • Fast response time • Corrosion resistance • Minimal touch control, data transmission
  • Performance Specification Table
  • Technical parameter table
    • Commodity name: Trace hydrogen chloride analyzer
    • Commodity ID: Puren-B HCl
    • 副标: Pure<sup>n</sup>-B HCl
    • Minor component:
    • Industry use: Special gas industry
    • Product model: Puren系列

    • PPB level measurement accuracy • Absolute measurement (no calibration required) • Low cost, maintenance free (no need for regular replacement/maintenance of sensors) • Fast response time • Corrosion resistance • Minimal touch control, data transmission

    Performance

    • Applicable gases: N2、H2、HCl

    • Detection range: see the technical parameter table for details

    • Lower limit of measurement: see technical parameter table for details

    • Sensitivity: ± 0.75% or 1/3LDL

    • Accuracy: ± 3% or LDL

    • Response speed:<1minute to 90%

     

    Electronic parameters

    • Alarm indication: system alarm

    • Power supply requirements: 100-240VAC, 50/60Hz

    • Power: 40W (MAX)

    • User interface: 7-inch LCD display screen

    • Signal output: 4-20mA output, RS485 output,
      adaptive network, RS-232 serial communication

     

    Air system and conditions

    • Working environment temperature: 10 ℃~40 ℃

    • Working environment relative humidity: 30% to 80% (without condensate)

    • Storage temperature: -10 ℃ -40 ℃

    • Pipeline material: Hastelloy alloy, Ra<0.25 μ M

    • Leak detection test:<1 × 10-9mbar l/sec

    • Inlet pressure: 0.05-0.8MPa

    • Maximum flow rate: approximately 1.5slm

    • Inlet gas temperature: up to 60 ℃

    • Inlet and outlet gas circuit: 1/4VCR male

     

    Other

    • Size: 630mm × 210mm × 220mm

    • Weight: 12Kg

    • Appearance: inclined or vertical panel

     

  • Tested gas and background gas

    HCl in N2

    HCl in H2

    HCl in HBr

    Measuring range

    0-20ppm

    0-10ppm

    0-100ppm

    Lower limit of measurement

    1.0ppb

    1.0ppb

    20.0ppb

    Sensitivity

    0.4ppb

    0.4ppb

    10.0ppb

Intent Message


* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.

Related Products


AE-CH2O

Formaldehyde analyzer

• Fast, continuous, real-time measurement • Excellent long-term stability and excellent accuracy • The instrument occupies small space and can meet different scenarios without the need for consumables • Easy and fast installation for on-site operation
View Details
AE-CH4

Methane analyzer

• Absolute measurement • Simple operation without frequent maintenance • Superior long-term stability and ultra-low drift • Measurement accuracy meets WMO standards
View Details

Domestic leading | National standards

Intent Message

Contact Information

Inner Mongolia Photonics Technologies Co., Ltd

Picture Name

Standardization Workshop of Science and Education Incubation Park, High-tech Industrial Park, Kangbashi District, Ordos City, Inner Mongolia Autonomous Region (west side of 4th floor of B2 Workshop)

Enterprise Public Number

Light Energy Technology

Copyright©2023 Inner Mongolia Light Energy Technology Co., Ltd

Powered by:300.cn Beijing | SEO

Business License
18647773203Yan Wenbin
13789770410Wang Rui
18647744777Qiao Xinyu
yanwenbin@nmggnkj.com

We will provide you with timely feedback